WhatsApp victor@gzkunling.com

MST-5100XPro 100 L/min Laser Airborne Particle Counter

High-performance, high-flow laser airborne particle counter for cleanroom classification and GMP-compliant environmental monitoring. 100 L/min sampling flow rate with six-channel particle size detection (0.5–25.0 μm).

MST-5100XPro Airborne Particle Counter

High-performance 100 L/min laser airborne particle counter for cleanroom classification, GMP-compliant environmental monitoring, and regulated industry validation.

100 L/min
Flow Rate
6
Size Channels
0.5 μm
Min. Detectable
10M
Records Storage

🌍
Global Supplier
50+ Countries Exported
🏭
Factory Direct
Manufacturer Pricing
Fast Delivery
3-7 Days Ready Stock
🔧
Technical Support
Engineer Assistance

Product Overview

The MST-5100XPro is a high-performance, high-flow laser airborne particle counter engineered for cleanroom classification, routine environmental monitoring, and GMP-compliant validation in regulated industries.

Designed to meet the stringent requirements of ISO 21501-4, ISO 14644-1, and FDA 21 CFR Part 11, the instrument delivers fast, accurate, and traceable particle measurement data for pharmaceutical, biotechnology, semiconductor, and medical device environments.

Why It Matters: With a 100 L/min sampling flow rate, the MST-5100XPro reduces cleanroom classification time by 3x compared to standard 28.3 L/min instruments, while six-channel particle size detection (0.5 – 25.0 μm) ensures comprehensive contamination monitoring.

Key Features

High-Flow Sampling
100 L/min flow rate enables rapid cleanroom classification, reducing measurement time by 3x vs. standard instruments.
🖥️
10″ Touchscreen Display
Industrial-grade capacitive touchscreen with real-time counts, trend graphs, and statistical analysis.
💾
10M Record Storage
Up to 10,000,000 measurement records with USB and Ethernet data export for seamless integration.
🔒
FDA 21 CFR Part 11
Full audit trail, multi-level user access control, and electronic signature support for regulated environments.
🏭
Cleanroom Compatible
Stainless steel housing with built-in HEPA exhaust filtration (>99.997% @ 0.3 μm) prevents contamination.
🔄
Self-Cleaning ≤ 10 min
Automated purge cycle minimizes downtime between sampling locations and prevents cross-contamination.
🎯
±3% Flow Accuracy
Mass flow controller ensures precise and stable airflow regulation for consistent measurement results.
📊
Room Management
Up to 50,000 rooms and 500,000 sampling points for large-scale facility monitoring.

Technical Specifications

Parameter Specification
Model MST-5100XPro
Instrument Type High-flow laser airborne particle counter
Sampling Flow Rate 100 L/min
Min. Detectable Size 0.5 μm
Particle Size Channels 0.5 / 1.0 / 3.0 / 5.0 / 10.0 / 25.0 μm
Display 10-inch industrial capacitive touchscreen
Light Source Semiconductor laser diode (≥30,000 hrs lifetime)
Sampling Time 1 s – 999,999 s programmable
Data Storage Up to 10,000,000 records
Communication USB / Ethernet
Printing Built-in thermal printer (optional Bluetooth)
Power Supply DC 16.8V rechargeable lithium battery
Housing Material Stainless steel, cleanroom compatible
Self-Cleaning Time ≤ 10 minutes
Max. Concentration 35,000 particles/L (≥0.5 μm)
Flow Control Accuracy ±3%
Alarm Functions Flow, laser, power, count, system, communication
Data Integrity Audit trail, user management, electronic signature
Room Management Up to 50,000 rooms / 500,000 sampling points

Applications

💊
Pharmaceutical
GMP cleanroom classification and routine monitoring
🧬
Biotechnology
Life science lab and production environment control
🔬
Semiconductor
Fab cleanroom surveillance and ISO classification
🏥
Medical Device
Production environment qualification and validation
🔧
HVAC Validation
System performance verification and commissioning
📋
Cleanroom Audit
Periodic qualification and regulatory audit support

Standards Compliance

The MST-5100XPro is designed and manufactured in compliance with the following international and national standards:

● ISO 14644-1
● ISO 21501-4
● GMP
● GB/T 29024.4-2017
● GB/T 25915.1-2021
● GB/T 16292-2025
● FDA 21 CFR Part 11

Why Choose GCC

🏭
Factory Direct Supply
Direct from manufacturer with competitive pricing. No middleman costs.
🌍
Global Export Experience
Equipment delivered to 50+ countries. Experienced with international compliance requirements.
🔧
Engineering Support
Dedicated engineers for pre-sales consultation and after-sales technical assistance.
Quality Control
Every unit calibrated and tested before shipment for reliable performance.
Fast Response
Quotation within 24 hours. WhatsApp and email support for urgent inquiries.
📋
Customized Solutions
Tailored configurations and accessory packages for specific project requirements.

Frequently Asked Questions

What is the measurement principle of the MST-5100XPro?
The MST-5100XPro uses a semiconductor laser diode light source combined with a photodetector. Airborne particles passing through the laser beam scatter light, which is detected and counted. The instrument simultaneously classifies particles into six size channels (0.5 – 25.0 μm) based on scattered light intensity.
How does the 100 L/min flow rate benefit cleanroom classification?
A 100 L/min flow rate samples approximately 3.5x more air volume per minute compared to standard 28.3 L/min instruments. This significantly reduces the time required for ISO 14644-1 cleanroom classification, improving operational efficiency without compromising measurement accuracy.
Is the MST-5100XPro suitable for pharmaceutical GMP environments?
Yes. The instrument is fully compliant with FDA 21 CFR Part 11 requirements, featuring multi-level user access control, electronic signatures, and a complete audit trail. The stainless steel housing with HEPA exhaust filtration ensures cleanroom compatibility for Grade A/B environments.
How many measurement records can be stored?
The MST-5100XPro supports up to 10,000,000 measurement records. Data can be exported via USB or Ethernet for integration with facility monitoring systems or compliance documentation.
What is the recommended calibration interval?
We recommend annual calibration per ISO 21501-4 requirements to maintain measurement traceability and compliance. GCC provides calibration services with traceable standard particle suspensions.
Can I manage multiple cleanroom locations with one unit?
Yes. The built-in room management system supports up to 50,000 rooms and 500,000 sampling points, making it ideal for large-scale pharmaceutical facilities, semiconductor fabs, and multi-site operations.

Need Technical Advice or Pricing?

Our engineers can help you select the right airborne particle counter for your cleanroom, pharmaceutical, or semiconductor project.

Contact GCC Cleanswan

Reviews

There are no reviews yet.

Be the first to review “MST-5100XPro 100 L/min Laser Airborne Particle Counter”

Your email address will not be published. Required fields are marked *